Does a property owner need an irrigator license to install a sprinkler system at their own home?
No, because the Texas Occupations Code exempts irrigation work a property owner does on premises the owner owns or occupies as a home.
Flashcards
33 free cards across the four exam sections, each one cited to the source it rests on. Reveal the back on any card. A free account keeps your place.
No, because the Texas Occupations Code exempts irrigation work a property owner does on premises the owner owns or occupies as a home.
24 hours of approved training credits, because renewing an irrigator license requires those hours on top of the general renewal requirements.
A final walk-through, the completed maintenance checklist, a permanent sticker on the controller (on the checklist if there is no automatic controller) and a copy of the design plan, because completing a new system with all four is one of the licensed irrigator's listed duties.
3 years from the date the work was completed, because the irrigator must hold records of installation, maintenance, alteration, repair and service for that period.
On the discharge side of the backflow prevention assembly, because a master valve provided on a new installation must sit downstream of the assembly.
A colored primer, because every new system built with PVC pipe and fittings must be primed with a colored primer before the PVC cement goes on.
Rain or moisture shut-off technology such as a rain sensor, because the Texas Commission on Environmental Quality (TCEQ) requires it on every new automatic system, except in the 14 counties the rule excludes by name (El Paso among them).
Between the water meter and the backflow prevention assembly, because every new system must include an isolation valve at that point, upstream of the assembly.
At least 6 in of select backfill over the pipe, because the Texas Commission on Environmental Quality (TCEQ) sets that as the minimum whenever the maker is silent on depth.
2 in of select backfill, because an unavoidable obstacle only lowers the 6 in minimum to a 2 in floor and never removes the cover.
Only wire that Underwriters Laboratories (UL) lists as fit for underground burial, because the rule allows nothing but UL-listed burial wire between an automatic controller and any electrical part.
At least 6 in of select backfill, because underground wiring from an automatic controller to any electrical component must be buried to that minimum depth.
At least twice the diameter of the water supply outlet and never less than 1.0 in, because the vertical separation must meet both the ratio and the 1 in floor.
An air gap, a reduced pressure principle backflow prevention assembly (RP), a pressure vacuum breaker (PVB) or a spill-resistant pressure vacuum breaker (SVB), each only when installed to its own conditions, because the rule as amended effective July 26, 2020 allows only those four types for a health hazard.
At least 12 in above ground, in a spot where it cannot be submerged, because an RP may serve a health hazard only when it is installed that way.
At least 12 in above all downstream piping and the highest downstream opening, because both vacuum breakers are held to that same minimum height over what they protect.
No. A DC may be used only where no condition presents a health hazard, and even then it must be tested on installation.
Every year, because assemblies on health hazard systems must be tested annually on top of the test at installation.
Through a reduced pressure principle backflow prevention assembly (RP) or an air gap, because adding a chemical by injection, aspiration or any other method requires one of those two.
Within ten business days of the test, because the irrigator must have the assembly tested before it goes into service and see that the results reach the purveyor in that window.
2.31 ft, because the Natural Resources Conservation Service (NRCS) conversion table sets 1 psi equal to 2.31 feet of head of water.
NRCS NEH Part 652, Irrigation Guide, p. 16-2 Reference document, not law.
0.433 psi, because the Natural Resources Conservation Service (NRCS) conversion table sets 1 foot of water head equal to 0.433 psi.
NRCS NEH Part 652, Irrigation Guide, p. 16-2 Reference document, not law.
35 pounds per square inch (psi) at every point, at flows of at least 1.5 gallons per minute (GPM) per connection, because Texas public water system rules set that design minimum.
The pressure of water that is not moving, and under Texas irrigation rules it is generally the pressure available to the irrigation system.
Add the head's minimum operating pressure to every pressure loss between that head and the water source, because Texas irrigation rules define design pressure as that sum.
5 feet per second (fps), because Texas irrigation rules require PVC piping to be designed and installed so the flow never goes past that velocity.
The zone or controller station number and the zone valve size, because since July 26, 2020 the plan must give each zone's flow measurement with both of those attached.
No more than plus or minus 10 percent, because since July 26, 2020 the rule caps spacing at that tolerance of the published radius or spacing for the head used.
When the strip is less than 48 in wide or long (hardscape not counted) and has walks or drives along two or more sides, because a new system must not use above-ground spray there.
No closer than 4 in, throwing away from the surface, because the rule sets that minimum from any hardscape and exempts only narrow paths and other small areas in public areas whose runoff drains to landscape. Since July 26, 2020 it applies to every installation, not only new systems.
Plant material type, microclimate, topography, soil conditions and hydrological needs, because the rule requires separate zones on each of those grounds.
The same precipitation rate, because every zone must be designed and installed so that all of its heads irrigate at one matched rate.
No, because a system must not spray water on or over any impervious surface, and concrete, asphalt, brick, wood, mortared stone, walls, fences, sidewalks and streets are all named.