Practice
Principles of Backflow practice
Sat and passed on its own: 70 percent to pass, 20 questions as candidates report it. 13 free questions here, 79 more in the paid bank.
All 13 free principles of backflow questions
-
Backflow in a water system can be caused by:
Either condition can carry irrigation water back into the potable supply, because Texas Commission on Environmental Quality (TCEQ) rules define backflow prevention as stopping a reversal of flow caused by back siphonage or by backpressure (30 TAC 344.1(3)).
-
Which backflow device does TCEQ NOT allow on a new irrigation system?
The Texas Commission on Environmental Quality (TCEQ) amended its landscape irrigation rule effective July 26, 2020 to replace the atmospheric vacuum breaker (AVB) with the spill-resistant vacuum breaker, because an AVB will not work correctly with a valve downstream. Since that date the AVB is no longer an allowed method on a new system (30 TAC 344.50(b)(4)).
30 TAC 344.50(b)(4); TCEQ, Quick Reference Guide to All Changes to 30 TAC Chapter 344 (2020), p. 18 Includes a reference document, not law.
-
Which backflow device may be set below ground?
The rule sets below-ground installation requirements only for double check valve assemblies (30 TAC 344.50(d)). The reduced pressure assembly must sit at least 12 inches above ground, and the vacuum breakers at least 12 inches above the highest downstream opening. A city may still bar the double check locally.
-
An air gap must be at least twice the outlet diameter and never less than:
The vertical separation of an air gap must be at least twice the diameter of the supply outlet, and it may never be less than 1.0 inch whatever size the outlet is (30 TAC 344.1(1)).
-
On a system designated a health hazard, the backflow assembly must be tested:
Assemblies on irrigation systems designated as health hazards must be tested annually, on top of the test every assembly gets on installation, repair, replacement or relocation (30 TAC 344.50(e)).
-
What causes backsiphonage?
Backsiphonage is backflow caused by supply pressure dropping below atmospheric pressure, because the vacuum in the supply line then pulls water back from the irrigation side. Pumps, raised heads and higher downstream pressure push water back instead, and that is backpressure.
RG-478, p. 5 Reference document, not law.
-
What condition creates backpressure?
Backpressure requires downstream pressure that overcomes the supply pressure and pushes water back toward the source. A drop in supply pressure, such as heavy hydrant use, pulls water back instead, and that is backsiphonage.
RG-478, p. 7 Reference document, not law.
-
What must a public water system be physically linked to for a cross-connection to exist?
A cross-connection exists only where a public water system is linked to a supply of unknown or questionable quality, a source that may contain contaminants, or water treated to a lesser degree (30 TAC 344.1(7)). Hydrants, meters and regulators are parts of the potable system itself and bring in no other source.
-
A PVB must be installed at least:
A pressure vacuum breaker (PVB) must sit at least 12 inches above all downstream piping and the highest downstream opening (30 TAC 344.50(b)(3)(B)). Its height is measured against the heads it serves, not against the ground.
-
How high above ground must an RP be installed?
A reduced pressure principle assembly (RP) must be installed at least 12 inches above ground in a place where it cannot be submerged, and drainage must be provided for water its relief valve discharges (30 TAC 344.50(b)(2)).
-
Water that is suitable for people to drink is called:
Potable water means water suitable for human consumption that meets the definition of drinking water (30 TAC 344.1(37)). Reclaimed water and graywater are both listed as non-potable sources and are not fit to drink.
-
An RP on a new system has just been tested. Within what time must the results reach the local water purveyor?
The irrigator must make sure the assembly is tested before the system goes into service and that the results reach the local water purveyor within ten business days of the test (30 TAC 344.52(c)).
-
Heads and piping set well above the backflow device can cause backflow by:
Backpressure is any rise in downstream pressure above the supply pressure, and the Texas Commission on Environmental Quality (TCEQ) guide RG-478 names elevation of piping as one cause alongside a pump. Heads and piping set high above the device therefore push water back toward the supply rather than pulling it.
RG-478, p. 6 Reference document, not law.
8 flashcards for Principles of Backflow
What this section covers
Keeping irrigation water out of the drinking water. Chapter 344 names the backflow methods an irrigation connection may use, the conditions that call for a stronger one, and how an assembly is installed and tested; Chapter 290 carries the drinking water side of the same rule.
The topics TCEQ's Basic Irrigator course outline lists for it:
- Backflow Prevention
Topics from the Basic Irrigator Training Course outline in TCEQ's curriculum guidance. TCEQ publishes no outline of the exam itself, so which section a topic sits under is this site's reading.